Project Record · WQ-2022-013Projects
Warehouse Perimeter and Fire System Integration
Perimeter intrusion detection linked to the fire alarm system for a logistics warehouse.
- Client
- Logistics warehousing
- Site
- Machong, Dongguan
- Scope
- 96 perimeter cameras / fire-lane obstruction detection / 8 loading docks
- Lead time
- 24 days
Quick summary
- Client: a logistics warehouse in Machong, Dongguan, with eight loading docks.
- Scope: 96 perimeter and fire-lane cameras, obstruction detection and alarms.
- Lead time: 24 days; key decision: detect lane occupancy only, not faces.
- Outcome: 98% lane-alarm accuracy, with local sound/light and a duty-room pop-up.
- Boundaries: excludes fire-host modification, sprinklers and WMS location management.
Perimeter surveillance and fire-alarm interlocking for a logistics warehouse in Machong, Dongguan, including eight loading docks and detection of blocked fire lanes. (Monitoring points: 96 · Delivery: 24 days · Lane-alarm accuracy: 98%)
Context
Two failures matter in a warehouse: someone entering the perimeter at night, and fire lanes blocked by goods during the day. The old CCTV only supported after-the-fact review, and lane blockages surfaced at inspection — often hours late.
Scope and exclusions
96 cameras for perimeter and lanes, coverage of eight loading docks, fire-lane obstruction detection and alerting. Fire panel modification, sprinklers and WMS were excluded.
- Included: perimeter, loading dock and fire-lane points with storage
- Included: obstruction detection with local sound-and-light alert and guard-room pop-up
- Excluded: fire panel integration, sprinkler control, WMS location management
Approach and key decisions
Detection targets lanes, not people: obstruction is judged by zone occupancy plus dwell time, with no facial capture, which meets the security need without privacy exposure. Alerts fire locally first and escalate to the guard room second, so one person is not flooded with every event.
- A dwell threshold avoids false alarms when a forklift merely passes through
- Tiered alerting: lane obstruction stays local, perimeter intrusion escalates to guard room and mobile
Deliverables and acceptance
Point maps, detection-zone configuration, alert rules and drill records. The 98% accuracy figure is the share of valid alerts during acceptance.
- Deliverables: as-built drawings, zone config, alert rules, drill records
- Acceptance: accuracy as valid alerts over total alerts, with every false positive explained
Common questions
Q: Why not use face recognition?
A: Occupancy is judged from zone boxes and dwell time, not faces, meeting the security need while avoiding privacy disputes.
Q: Will a passing forklift trigger a false alarm?
A: A minimum dwell time is applied, so a brief pass-through does not alarm.
Q: How is 98% accuracy calculated?
A: Valid alarms divided by total alarms; every false alarm is logged with a cause.
FAQ
Frequently asked questions
- 01Why no facial recognition?
- AnswerOnly zone intrusion and dwell time are assessed; no faces are captured. That meets the security requirement while avoiding privacy disputes.
- 02Will a passing forklift trigger a false alarm?
- AnswerThe occupancy rule has a minimum dwell time, so a vehicle passing through does not raise an alarm.
- 03How is the 98% accuracy calculated?
- AnswerAs valid alarms divided by total alarms, with the cause of each false alarm logged.
NEXT · WHAT HAPPENS AFTER
Need an assessment for a similar site?
We survey site points, cabling and power first, then quote the design, bill of materials and installation boundary.